Fairchild Chimney Company | Inspections

Level 1 or Level 2 for a Rental

Own Units Like These?

By sending, you agree Fairchild Chimney Company may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Fireplace with a fire below a TV between white shelves

Two prices, one question

On a rental property, the choice between inspection levels is mostly a budget question with a safety answer. Our Level 1 costs $160 per fireplace. Our Level 2 costs $375 per fireplace. On a twelve-unit building in Costa Mesa that is the difference between a modest line and a large one, so owners rightly ask when the bigger figure is earned.

The short answer: Level 1 is the yearly routine; Level 2 is for moments when something about the chimney, the owner or the fuel has changed.

What each level actually looks at

Both levels follow the national fireplace and chimney standard, NFPA 211, which sorts the work by how deep the inspector has to go.

  • At Level 1 we look at what is open to view from the room, the roof and any accessible attic: the firebox and its brick, the damper, the opening to the flue, the crown, the cap and the roof joint. We confirm nothing is blocking the flue and that the fireplace is fit to keep using as it has been.
  • At Level 2 we do all of that and send a camera the length of the flue, recording the condition of each section of liner, the joints between them and the smoke chamber. We also look at the parts of the chimney that pass through attics and crawl spaces and at clearances to the framing where they can be reached.
  • Level 3 means opening a wall or removing masonry to reach a hidden part. It comes up only when Level 2 points at a serious problem that cannot be judged any other way, and it is scoped on its own.

Which level fits which moment

Moment in the life of a rentalLevel we suggestReason
Yearly check, same tenant, same fuelLevel 1Nothing has changed since last year's page
New tenant after a short turnoverLevel 1A clean record at move-in
Building sold or refinancedLevel 2The standard calls for it at a change of owner, and lenders ask
Wood unit converted to gas or fitted with an insertLevel 2The flue has to suit the new appliance
After a chimney fire in a unitLevel 2Heat damage hides inside the flue
After a strong earthquakeLevel 2Cracks open in places nobody sees from the hearth
Level 1 finds something it cannot judgeLevel 2 on that unitOnly the camera can answer it
Unit vacant for a long time, then reopenedLevel 1, Level 2 if the top shows damageNests and water are common in shut chimneys

The rows that call for a Level 2 rarely apply to every fireplace at once. In a typical year on a mid-size property, most fireplaces get a Level 1 and a few get the camera.

Pricing a mixed round

A round that mixes the two is priced line by line: $160 for each fireplace at Level 1, $375 for each at Level 2, plus a sweep from $400 where a wood flue needs one before the camera can see the tile. Gas units still get inspected; the camera looks at their venting just as it would a wood flue.

If you are unsure which level a building needs this year, use the quote form to say what has changed since the last inspection: a sale, a conversion, a tenant report or simply another year. We come back with the suggested level per fireplace and the total.

Why the coast and the faults matter here

Two local facts push some Costa Mesa rentals toward the camera sooner than an inland building would be.

  • Quakes. Southern California brick chimneys took heavy damage in the 1994 quake, and smaller shakes since have tested the same mortar. A building that has never had a Level 2 has no baseline to measure the next shake against.
  • Marine air. Damp salty air corrodes metal liners and steel dampers faster near the water. A metal liner put in twenty years ago in Newport Beach may look fine at the top and be thin lower down.

What the owner gets at each level

Both levels produce a dated page per fireplace with photos and a plain grade. A Level 2 page adds still frames from the camera at each problem spot, so a lender or buyer sees the flue itself rather than a description of it. The office can file either one by unit number and forward it without editing.

A rule of thumb for the budget

Plan a Level 1 for every fireplace every year. Hold a Level 2 line for the units that have had a change: a sale, a new appliance, a fire, a quake, or a finding. Give a building its first Level 2 once, so later years have something to compare against.

When the buyer of your building asks for more

Owners selling a rental building in Costa Mesa or Fountain Valley sometimes discover the buyer's inspector has written "recommend further evaluation" next to every fireplace. A stack of Level 1 pages from past years helps, but it does not answer that line, because the buyer wants to know what is inside the flue today. Booking the Level 2 round before the building is listed puts that answer in the disclosure file and lets the seller decide which findings to repair and which to price into the sale. The home sale page explains who receives the report in that case and how copies go to each agent.

Getting started

To set the right level for each fireplace on your properties, begin on our contact page.

Putting This on Your Property Calendar?

Fairchild books rental chimney and fireplace work by unit, agrees access with tenants and files a dated page for each fireplace. Rounds leave Costa Mesa for Fountain Valley, Tustin, Newport Beach and the rest of Orange County.

Call (949) 879-2593