Fairchild Chimney Company | Gas Fireplaces

Gas Fireplace Care for Rentals

Own Units Like These?

By sending, you agree Fairchild Chimney Company may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Spacious living room featuring a fireplace, leather furniture, and large windows with natural light.

The fireplace tenants never think about

Tenants treat a gas fireplace like a light switch. They press a button, flames appear, and nobody looks behind the glass again until it turns grey or the pilot refuses to catch on the first cold evening. In a building of twelve or forty units in Costa Mesa, that adds up to a dozen small faults hiding behind glass fronts, each one a call to the office in December.

A gas fireplace cleaning visit puts every unit through the same check in one round, and the office receives one dated page per unit saying what was found and what was done.

Inside each unit

The work in a unit follows the same order every time, so the pages compare cleanly across a building.

  • Gas off, glass out. We close the unit's shutoff, let the box cool and lift the glass front away.
  • The film on the glass. Burning gas leaves a white mineral haze on the inner face. It comes off during the visit; left for years, it etches.
  • Logs and burner. The ceramic logs come out so the burner ports can be brushed and the ember material reset where the maker intended.
  • Control space. The cavity under the firebox collects lint, pet hair and dust around the valve. We clear it and look at the wiring and the igniter.
  • Pilot and sensor. Scale on the pilot hood or the flame sensor is the usual reason a unit lights on the fifth try. We note what we see.
  • Gasket and frame. A flattened or torn seal around the glass frame lets exhaust into the room on sealed units.
  • Relight and vent. We relight, watch the flame carry across the burner and look at the outside termination for vines, nests and crushed hoods.
  • Alarm. We record whether the unit has a carbon monoxide alarm mounted and whether it answers its test button.

Findings that repeat across a building

What we seeWhat it usually points toNext move
Hard white haze on the glassNormal combustion residueCleaned on the visit
Pilot that needs several triesDirty pilot or a tired sensorWritten as a gas repair line
Flames lifting off the burnerAir and gas mix out of balanceAdjusted, or written as a repair
Outside vent hood choked by a vineGrowth or nestingCleared where it can be reached
Cracked glassImpact or heat stressPage opens with "do not use until replaced"
Dead remote or wall switchBatteries or loose wiringNoted for the office

Setting the per-unit figure

This site does not print a figure for gas fireplace cleaning, because a building changes the work. One model throughout goes quickly; a building where owners swapped units over twenty years means a different part list in every living room. Roof access to the vent terminations, parking for the van and how many units sit empty also play in.

We set one per-unit figure for the building once we know the unit count and the mix of models, and it is in writing before the first glass comes off. Repairs found during the round are listed per unit with the part and its figure, and the office approves them unit by unit. Vented units that run up a metal pipe through the roof can also take a Level 1 at $160 per fireplace for the vent side.

To get the building figure, use the quote form to give the address, the number of gas units and, if an old invoice shows it, the model name of the fireplaces.

Working around tenants

Most gas rounds happen in occupied buildings, so the plan starts with the people living there.

  • Notice. The office sends the written entry notice its leases already require, with the window we have agreed.
  • Order. We work in the order the office sets, floor by floor or building by building, so tenants know roughly when we will knock.
  • Keys. Units where nobody will be in need a key from the office or a lockbox code. A unit we cannot enter goes on the summary as "not reached", never as cleaned.
  • Clean floors. Drop cloths go down at the door and the hearth; the glass is cleaned on a pad, not on the tenant's furniture.

What the office keeps

A summary sheet lists every unit with one of three statuses: cleaned, cleaned with a repair noted, not reached. Behind it sits one page per unit with the unit number, the model if the rating plate is readable, photos of the glass before and after, and any repair with its figure. That page answers a tenant complaint, an owner's question or an insurer's request without anyone writing a new letter.

Mixed buildings

Older complexes in Costa Mesa, Tustin and Fountain Valley often mix fuels. Some units keep the original wood fireplace, others had gas log sets or sealed inserts added by past owners. We put both types on one round: wood units get a sweep or a Level 1, gas units get the cleaning, and the summary sheet sorts them so the office can see the whole property at a glance.

When a tenant reports a problem between rounds

A yearly round does not stop a pilot from failing in February. When a tenant calls about a unit that will not light, a smell near the glass or a fan that rattles, the office can book that single unit on its own. The page from the last round tells us the model and what was noted then, which shortens the visit, and the new page goes into the same file. If anyone in the unit smells gas, the first call is to the gas utility, not to us; we come once the utility has cleared the line.

Booking a round

When the office is ready to put every gas unit on one schedule, start from our contact page and we will set the order with you.

Putting This on Your Property Calendar?

Fairchild books rental chimney and fireplace work by unit, agrees access with tenants and files a dated page for each fireplace. Rounds leave Costa Mesa for Fountain Valley, Tustin, Newport Beach and the rest of Orange County.

Call (949) 879-2593