Your Level 2 came back with findings. Here is what they mean
Turn findings into a scope
Give the address and list the findings from the report in your own words. We reply with which items carry a published figure and arrange a visit for the rest.
Findings that fail a Level 2
These are the items that come up again and again on camera inspections of older houses and rental buildings around Costa Mesa. A report may list one or several.
- Cracked, shifted or missing sections of clay flue tile.
- Open joints between tile sections, where heat and gases reach the brick.
- No cover on the flue, or a rusted one that no longer stops rain and animals.
- A crown with cracks running through it, or one that was never more than a thin mortar wash.
- Water marks inside the flue or smoke chamber, pointing to a leak at the top or at the roof joint.
- A damper rusted shut, rusted open or missing its plate.
- A gas appliance venting into a flue sized for wood, with condensation marks.
- Wood framing or trim closer to the chimney than the standard allows.
What each finding usually leads to
Tile damage and open joints lead to relining: a stainless liner run inside the old flue, sized to whatever the fireplace or appliance will burn. A flue that will only ever serve gas can sometimes be answered more simply by setting a sealed gas unit in the old opening, which carries its own vent up the chimney.
Missing or rusted covers lead to a new cap. Water marks lead to a leak trace and a fix at the source, which on a wide chimney facing up the roof often includes a small peaked diverter behind it. Crowns get repaired or recast. Dampers get replaced or swapped for a type that seals at the top. Clearance problems need a site visit to see how the framing was built.
Figures we publish and items we scope
Leak work, diverter peaks and gas conversions have published ranges, listed below. Where a job falls in its range depends on the size of the chimney, how many flues it carries and how hard the roof is to work on. A cap is quoted after we measure.
Relining, crown work, damper replacement, chase covers and roof-joint metal on its own change too much from one chimney to the next for a single figure. Each one goes on a written scope per fireplace after a visit, with the materials named and a figure the owner approves before work begins.
Closing the file after repairs
A failed report stays failed in the file until something shows the work was done. When we finish a repair, we photograph it and add a dated note to the original fireplace page. In a sale, both agents receive the update if the client names them. On a rental, the manager gets the page for the unit file, ready for the next insurer or lender who asks.
Published repair figures
These are the fixes with a set range on this site. Everything else on a failed report gets a written scope per fireplace. The cap row is quoted after we measure the flue.
- Stopping water at its source
- $535 to $3,200
- Diverter peak on the high side of the stack
- $425 to $960
- Diverter peak plus fresh roof-joint metal
- $640 to $1,600
- Sealed gas heater set in an existing opening
- $2,650 to $5,350
- Follow-up camera pass on a repaired flue
- $375
- New top over one or more flues
- Quoted after we measure
Ranges cover the installed work. The position within each range depends on the chimney's size, its number of flues and access to the roof.
Questions after a failed report
Does a failed Level 2 mean the fireplace cannot be used?
It depends on the finding. A missing cap is a weather problem; open tile joints near the firebox are a fire problem. The report grades each item, and anything marked unsafe should not be used until repaired.
Can you work from another company's report?
We read it to understand the findings, but we visit before writing a scope. The repair has to match what is in the chimney today, not a description of it.
Is converting to gas cheaper than relining for wood?
Sometimes. A sealed gas unit brings its own vent, so a damaged flue may not need a full wood liner. Whether that holds depends on the flue and the room, which the visit settles.
Who should sign the repair scope in a sale?
The party paying for the work. That is agreed between buyer and seller through their agents; we take the signature of whoever the agreement names.
How does the report show the repair was done?
We add dated photos and a note to the original fireplace page, and send the update to everyone on the client's list.
Bring the failed report
Send the address and the report findings through our contact page. We sort them into items with set prices and items that need a visit first.
Call (949) 879-2593